Abstract
IVIM imaging technology can obtain physiological information of tissue cells and blood perfusion at the same time in one imaging process. Taking female patients in Shenzhen Maternal and Child Health Hospital affiliated to Southern Medical University as an example, the migration and movement of breast cancer cells and hepatocellular carcinoma cells are studied by intravoxel incoherent motion imaging. Apparent diffusion coefficient (ADC), true diffusion coefficient (D), pseudo-diffusion coefficient (D*) and perfusion fraction (f) are measured by the IVIM bi-index model, and statistical analysis is made. The results show that the IVIM bi-index model can truly reflect the diffusion of water molecules in breast mass-like lesions, and reflect the migration and movement of breast cancer cells. Especially D value has important reference significance for the research and diagnosis of breast cancer cells. IVIM bi-index model has limited diagnostic value for the migration and movement of common hepatocellular carcinoma cells, and ADC value may have higher diagnostic efficiency.
Keywords
Download Citation
Endnote/Zotero/Mendeley (RIS)BibTeX
- Yan C, Xu J, Xiong W, Wei Q, Feng R, Wu Y, Liu Q, Li C, Chan Q, Xu Y. Use of intravoxel incoherent motion diffusion-weighted MR imaging for assessment of treatment response to invasive fungal infection in the lung. Eur Radiol 2017; 27(1):212-21.
- Meeus E, Novak J, Withey S. Evaluation of intravoxel incoherent motion fitting methods in low-perfused tissue. J Magn Reson Imaging 2017; 45: 1325-1334.
- Yan N. Resisting power attacks scheme based on signed integer splitting form. J Chin Acad Electron Inf Technol 2017; 12: 438-442.
- Rong D, Mao Y, Hu W. Intravoxel incoherent motion magnetic resonance imaging for differentiating metastatic and non-metastatic lymph nodes in pancreatic ductal adenocarcinoma. Eur Radiol 2018; 28: 2781-2789.
- Sun L, Zhang Y, Chen X. Repetitive-control-based control technology for microgrid inverters. J Power Supply 2018; 16: 38-44.
- Zhang C, Wong S, Uiterwijk R. Intravoxel incoherent motion imaging in small vessel disease. Stroke, 2017; 48: 658-663.
- Zhang X, Lang Y. Power management and implementation based on ethernet switch. Chin J Power Sources 2017; 41: 630-632.
- Liu Y, Li H, Zhang J.. Potassium iodate differently regulates the proliferation, migration, and invasion of human thyroid cancer cells via modulating mir-146a. Cancer Invest 2017; 35: 122-128.
- Hu Y. Main problems and solutions of mechanical and electrical equipment installation in intelligent building branch project. Autom Instrum 2017; 4: 159-161.
- Woo S, Suh C Kim, S. Magnetic resonance imaging for detection of parametrial invasion in cervical cancer: An updated systematic review and meta-analysis of the literature between 2012 and 2016. European Radiology, 28: 1-12.
- Lin, W.X., 2017. Oscillation analysis for a class of even order neutral differential equations with damping terms. J Jilin Univ (Science Edition), 2017; 55: 1073-1076.
- Sun Y, Xiao Q, Hu F. Diffusion kurtosis imaging in the characterisation of rectal cancer: utilizing the most repeatable region-of-interest strategy for diffusion parameters on a 3T scanner. Eur Radiol 2018; 28: 1-10.
- Ding S. Accurate evaluation and simulation of load carrying risk of building bearing column. Comput Simul 2018; 35: 349-352.
- Zhou Y, Xu Q, Shang J. Crocin inhibits the migration, invasion, and epithelial-mesenchymal transition of gastric cancer cells via miR-320/KLF5/HIF-1α signaling. J Cell Physiol 2019; 234: 17876-17885.
- Godbole M, Tiwary K, Badwe R. Progesterone suppresses the invasion and migration of breast cancer cells irrespective of their progesterone receptor status - a short report. Cell Oncol 2017; 40: 411-417.
- Niu J, Li W, Wang H. Intravoxel incoherent motion diffusion-weighted imaging of bone marrow in patients with acute myeloid leukemia: a pilot study of prognostic value. J Magn Reson Imaging 2017; 46: 476-482.
- Zhang C, Wong S, Uiterwijk R. Intravoxel incoherent motion imaging in small vessel disease: microstructural integrity and microvascular perfusion related to cognition. Stroke 2017; 48: 658-663.
- Gao Q, Lu S, Xu X. Quantitative assessment of hyperacute cerebral infarction with intravoxel incoherent motion MR imaging: Initial experience in a canine stroke model. J Magn Reson Imaging 2017; 46: 550-556.
- Wengler K, Fukuda T, Tank D. Intravoxel incoherent motion (IVIM) imaging in human achilles tendon. J Magn Reson Imaging 2018; 48: 1690-1699.
- Li X, Wang P, Li D. Intravoxel incoherent motion MR imaging of early cervical carcinoma: correlation between imaging parameters and tumor-stroma ratio. Eur Radiol 2017; 28: 1-9.
- Peng WX, Wang LS, Mirzaee M, Ahmadi H, Esfahani MJ, Fremaux S. Hydrogen and syngas production by catalytic biomass gasification. Energy Convers Manag 2017; 135:270-3.
- Peng WX, Ge SB, Ebadi AG, Hisoriev H, Esfahani MJ. Syngas production by catalytic co-gasification of coal-biomass blends in a circulating fluidized bed gasifier. J Clean Prod 2017; 168:1513-7.
- Peng W, Lin Z, Wang L, Chang J, Gu F, Zhu X. Molecular characteristics of Illicium verum extractives to activate acquired immune response. Saudi J Biol Sci 2016; 23(3): 348-52.
- Liang X, Shi W, Wang X, Qin J, Wang L, Wu X, et al. Brainstem schwannoma: A case report and review of clinical and imaging features. Int J Radiat Res. 2020; 18 (3) :605-610
- Tayeri H, Sattarzadeh Khameneh E, Zolghadri S, Kakaei S, Sardari D. Optimized production, quality control and biological assessment of 68-Ga-bleomycin as a possible PET imaging agent. Int J Radiat Res. 2020; 18 (2) :235-241.
- Ahmadi N, Karimian A, Nasrabadi M, Rahmim A. Assessment of fetal and maternal radiation absorbed dose in 18F-FDG PET imaging. Int J Radiat Res. 2019; 17 (4) :651-657.
- Salimi Y, Deevband M, Ghafarian P, Ay M. Uncertainties in effective dose estimation for CT transmission scan in total body PET-CT imaging with Auto mA3D tube current modulation . Int J Radiat Res. 2018; 16 (4) :465-472.
- Abtahi S, Jafari Khalilabadi R, Aftabi S. An investigation into the effect of magnetic resonance imaging (MRI) echo time spacing and number of echoes on the sensitivity and dose resolution of PAGATUG polymer-gel dosimeter. Int J Radiat Res. 2017; 15 (2) :185-196.
- Heck K, Korkusuz Y, Happel C, Grünwald F, Korkusuz H. Percutaneous microwave ablation of thyroid nodules: efficacy evaluation with 99m Tc - pertechnetate and 99mTc-MIBI functional imaging. Int J Radiat Res. 2016; 14 (2) :91-98.
- Salihin Yusoff M, Zakaria A. Determination of the optimum filter for qualitative and quantitative 99mTc myocardial SPECT imaging. Int J Radiat Res. 2009; 6 (4) :173-182.
- Jalilian A, Mirazizi F, Nazem H, Garousi J, Bolourinovin F, Sadeghpour H. Preparation and quality control of radiolabeled streptokinase for Thrombosis imaging. Int J Radiat Res. 2009; 6 (4) :195-200.
- Azadbakht B, Zahmatkesh M, Hadad K, Bagheri S. Verification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging. Int J Radiat Res. 2008; 6 (2) :83-87.
- Khosravi H, Sarkar S, Takavar A, Saghari M, Shahriari M. Planar and SPECT Monte Carlo acceleration using a variance reduction technique in I131 imaging. Int J Radiat Res. 2007; 4 (4) :175-182.
- Liu X, Shen C. Correlation of ultrasound perfusion imaging and angiogenesis of ovarian tumors. Int J Radiat Res. 2019; 17 (4) :559-567.
- Choi J, Rim C, Kim Y, Yang D. Cumulative radiation exposure dose of diagnostic imaging studies in breast cancer patients. Int J Radiat Res. 2019; 17 (2) :275-281.
- Chen H, Huang H, Li G, Huang D, Huang S, Wang Z. Application of computed tomography and magnetic resonance imaging fusion images for delineating gross tumor volume in three-dimensional conformal radiotherapy of nasopharyngeal carcinoma. Int J Radiat Res. 2017; 15 (3) :251-257.
- Mahdavi S R, Jazayeri Gharehbagh E, Mofid B, Jafari A H, Nikoofar A R. Accuracy of the dose delivery in prostate cancer patients-using an electronic portal imaging device (EPID) . Int J Radiat Res. 2017; 15 (1) :39-47.
- Robatjazi M, Mahdavi S, Nikofar A, Bolouri B, Baghani H. Optimization of clinical target volume delineation using magnetic resonance spectroscopic imaging (MRSI) in 3D conformal radiotherapy of prostate cancer. Int J Radiat Res. 2014; 12 (4) :303-309.
- Jomehzadeh A, Shokrani P, Mohammadi M, Amouheidari A. A quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes . Int J Radiat Res. 2014; 12 (3) :257-264.
- Teimoori Sichani M, Amoui M, Akhlaghpoor S, Hosntalab M. Quantitative SPECT and planar 32P bremsstrahlung imaging for dosimetry purpose –An experimental phantom study. Int J Radiat Res. 2014; 12 (2) :129-138.
- Jalilian AR, Fateh B, Ghergherehchi M, Karimian A, Matlloobi M. Preparation, distribution, stability and tumor imaging properties of [62Zn] bleomycin complex in normal and tumor-bearing mice. Int J Radiat Res. 2003; 1 (1) :37-44.
- He X, Zheng J, Ren J, Zheng G, Liu L. Chest high-resolution computed tomography imaging findings of coronavirus disease 2019 (Covid-19) pneumonia. Int J Radiat Res. 2020; 18 (2) :343-349.
- Falahatgar D, Farajnia S, Zarghami N, Tanomand A, Khosroshahi SA, Akbari B, Farajnia H. Expression and Evaluation of HuscFv Antibody -PE40 Immunotoxin for Target Therapy of EGFR-Overexpressing Cancers. Iran J Biotechnol. 2018; 16(4): e1743.
- Avand A, Akbari V, Shafizadegan S. In Vitro Cytotoxic Activity of a Lactococcus lactis Antimicrobial Peptide Against Breast Cancer Cells. Iran J Biotechnol. 2018; 16(3): e1867.
- Bahadori M, Baharara J, Amini E. Anticancer Properties of Chrysin on Colon Cancer Cells, In vitro and In vivo with Modulation of Caspase-3, -9, Bax and Sall4. Iran J Biotechnol. 2016; 14(3): 177-184.
- Behfarjam F, Rostamzadeh J, Zarei MA, Nikkhoo B. Association of Two Polymorphic Codons in P53 and ABCC1 Promoter with Prostate Cancer. Iran J Biotechnol. 2015; 13(1): 49-54.
- Bordbar M, Darvishzadeh R, Pazhouhandeh M, Kahrizi D. An overview of genome editing methods based on endonucleases. Mod Genet J 2020; 15(2): 75-92.
- Jamalzadeh L, Ghafoori H, Aghamaali M, Sariri R. Induction of Apoptosis in Human Breast Cancer MCF-7 Cells by a Semi-Synthetic Derivative of Artemisinin: A Caspase-Related Mechanism. Iran J Biotechnol. 2017; 15(3): 157-165.
References
Yan C, Xu J, Xiong W, Wei Q, Feng R, Wu Y, Liu Q, Li C, Chan Q, Xu Y. Use of intravoxel incoherent motion diffusion-weighted MR imaging for assessment of treatment response to invasive fungal infection in the lung. Eur Radiol 2017; 27(1):212-21.
Meeus E, Novak J, Withey S. Evaluation of intravoxel incoherent motion fitting methods in low-perfused tissue. J Magn Reson Imaging 2017; 45: 1325-1334.
Yan N. Resisting power attacks scheme based on signed integer splitting form. J Chin Acad Electron Inf Technol 2017; 12: 438-442.
Rong D, Mao Y, Hu W. Intravoxel incoherent motion magnetic resonance imaging for differentiating metastatic and non-metastatic lymph nodes in pancreatic ductal adenocarcinoma. Eur Radiol 2018; 28: 2781-2789.
Sun L, Zhang Y, Chen X. Repetitive-control-based control technology for microgrid inverters. J Power Supply 2018; 16: 38-44.
Zhang C, Wong S, Uiterwijk R. Intravoxel incoherent motion imaging in small vessel disease. Stroke, 2017; 48: 658-663.
Zhang X, Lang Y. Power management and implementation based on ethernet switch. Chin J Power Sources 2017; 41: 630-632.
Liu Y, Li H, Zhang J.. Potassium iodate differently regulates the proliferation, migration, and invasion of human thyroid cancer cells via modulating mir-146a. Cancer Invest 2017; 35: 122-128.
Hu Y. Main problems and solutions of mechanical and electrical equipment installation in intelligent building branch project. Autom Instrum 2017; 4: 159-161.
Woo S, Suh C Kim, S. Magnetic resonance imaging for detection of parametrial invasion in cervical cancer: An updated systematic review and meta-analysis of the literature between 2012 and 2016. European Radiology, 28: 1-12.
Lin, W.X., 2017. Oscillation analysis for a class of even order neutral differential equations with damping terms. J Jilin Univ (Science Edition), 2017; 55: 1073-1076.
Sun Y, Xiao Q, Hu F. Diffusion kurtosis imaging in the characterisation of rectal cancer: utilizing the most repeatable region-of-interest strategy for diffusion parameters on a 3T scanner. Eur Radiol 2018; 28: 1-10.
Ding S. Accurate evaluation and simulation of load carrying risk of building bearing column. Comput Simul 2018; 35: 349-352.
Zhou Y, Xu Q, Shang J. Crocin inhibits the migration, invasion, and epithelial-mesenchymal transition of gastric cancer cells via miR-320/KLF5/HIF-1α signaling. J Cell Physiol 2019; 234: 17876-17885.
Godbole M, Tiwary K, Badwe R. Progesterone suppresses the invasion and migration of breast cancer cells irrespective of their progesterone receptor status - a short report. Cell Oncol 2017; 40: 411-417.
Niu J, Li W, Wang H. Intravoxel incoherent motion diffusion-weighted imaging of bone marrow in patients with acute myeloid leukemia: a pilot study of prognostic value. J Magn Reson Imaging 2017; 46: 476-482.
Zhang C, Wong S, Uiterwijk R. Intravoxel incoherent motion imaging in small vessel disease: microstructural integrity and microvascular perfusion related to cognition. Stroke 2017; 48: 658-663.
Gao Q, Lu S, Xu X. Quantitative assessment of hyperacute cerebral infarction with intravoxel incoherent motion MR imaging: Initial experience in a canine stroke model. J Magn Reson Imaging 2017; 46: 550-556.
Wengler K, Fukuda T, Tank D. Intravoxel incoherent motion (IVIM) imaging in human achilles tendon. J Magn Reson Imaging 2018; 48: 1690-1699.
Li X, Wang P, Li D. Intravoxel incoherent motion MR imaging of early cervical carcinoma: correlation between imaging parameters and tumor-stroma ratio. Eur Radiol 2017; 28: 1-9.
Peng WX, Wang LS, Mirzaee M, Ahmadi H, Esfahani MJ, Fremaux S. Hydrogen and syngas production by catalytic biomass gasification. Energy Convers Manag 2017; 135:270-3.
Peng WX, Ge SB, Ebadi AG, Hisoriev H, Esfahani MJ. Syngas production by catalytic co-gasification of coal-biomass blends in a circulating fluidized bed gasifier. J Clean Prod 2017; 168:1513-7.
Peng W, Lin Z, Wang L, Chang J, Gu F, Zhu X. Molecular characteristics of Illicium verum extractives to activate acquired immune response. Saudi J Biol Sci 2016; 23(3): 348-52.
Liang X, Shi W, Wang X, Qin J, Wang L, Wu X, et al. Brainstem schwannoma: A case report and review of clinical and imaging features. Int J Radiat Res. 2020; 18 (3) :605-610
Tayeri H, Sattarzadeh Khameneh E, Zolghadri S, Kakaei S, Sardari D. Optimized production, quality control and biological assessment of 68-Ga-bleomycin as a possible PET imaging agent. Int J Radiat Res. 2020; 18 (2) :235-241.
Ahmadi N, Karimian A, Nasrabadi M, Rahmim A. Assessment of fetal and maternal radiation absorbed dose in 18F-FDG PET imaging. Int J Radiat Res. 2019; 17 (4) :651-657.
Salimi Y, Deevband M, Ghafarian P, Ay M. Uncertainties in effective dose estimation for CT transmission scan in total body PET-CT imaging with Auto mA3D tube current modulation . Int J Radiat Res. 2018; 16 (4) :465-472.
Abtahi S, Jafari Khalilabadi R, Aftabi S. An investigation into the effect of magnetic resonance imaging (MRI) echo time spacing and number of echoes on the sensitivity and dose resolution of PAGATUG polymer-gel dosimeter. Int J Radiat Res. 2017; 15 (2) :185-196.
Heck K, Korkusuz Y, Happel C, Grünwald F, Korkusuz H. Percutaneous microwave ablation of thyroid nodules: efficacy evaluation with 99m Tc - pertechnetate and 99mTc-MIBI functional imaging. Int J Radiat Res. 2016; 14 (2) :91-98.
Salihin Yusoff M, Zakaria A. Determination of the optimum filter for qualitative and quantitative 99mTc myocardial SPECT imaging. Int J Radiat Res. 2009; 6 (4) :173-182.
Jalilian A, Mirazizi F, Nazem H, Garousi J, Bolourinovin F, Sadeghpour H. Preparation and quality control of radiolabeled streptokinase for Thrombosis imaging. Int J Radiat Res. 2009; 6 (4) :195-200.
Azadbakht B, Zahmatkesh M, Hadad K, Bagheri S. Verification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging. Int J Radiat Res. 2008; 6 (2) :83-87.
Khosravi H, Sarkar S, Takavar A, Saghari M, Shahriari M. Planar and SPECT Monte Carlo acceleration using a variance reduction technique in I131 imaging. Int J Radiat Res. 2007; 4 (4) :175-182.
Liu X, Shen C. Correlation of ultrasound perfusion imaging and angiogenesis of ovarian tumors. Int J Radiat Res. 2019; 17 (4) :559-567.
Choi J, Rim C, Kim Y, Yang D. Cumulative radiation exposure dose of diagnostic imaging studies in breast cancer patients. Int J Radiat Res. 2019; 17 (2) :275-281.
Chen H, Huang H, Li G, Huang D, Huang S, Wang Z. Application of computed tomography and magnetic resonance imaging fusion images for delineating gross tumor volume in three-dimensional conformal radiotherapy of nasopharyngeal carcinoma. Int J Radiat Res. 2017; 15 (3) :251-257.
Mahdavi S R, Jazayeri Gharehbagh E, Mofid B, Jafari A H, Nikoofar A R. Accuracy of the dose delivery in prostate cancer patients-using an electronic portal imaging device (EPID) . Int J Radiat Res. 2017; 15 (1) :39-47.
Robatjazi M, Mahdavi S, Nikofar A, Bolouri B, Baghani H. Optimization of clinical target volume delineation using magnetic resonance spectroscopic imaging (MRSI) in 3D conformal radiotherapy of prostate cancer. Int J Radiat Res. 2014; 12 (4) :303-309.
Jomehzadeh A, Shokrani P, Mohammadi M, Amouheidari A. A quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes . Int J Radiat Res. 2014; 12 (3) :257-264.
Teimoori Sichani M, Amoui M, Akhlaghpoor S, Hosntalab M. Quantitative SPECT and planar 32P bremsstrahlung imaging for dosimetry purpose –An experimental phantom study. Int J Radiat Res. 2014; 12 (2) :129-138.
Jalilian AR, Fateh B, Ghergherehchi M, Karimian A, Matlloobi M. Preparation, distribution, stability and tumor imaging properties of [62Zn] bleomycin complex in normal and tumor-bearing mice. Int J Radiat Res. 2003; 1 (1) :37-44.
He X, Zheng J, Ren J, Zheng G, Liu L. Chest high-resolution computed tomography imaging findings of coronavirus disease 2019 (Covid-19) pneumonia. Int J Radiat Res. 2020; 18 (2) :343-349.
Falahatgar D, Farajnia S, Zarghami N, Tanomand A, Khosroshahi SA, Akbari B, Farajnia H. Expression and Evaluation of HuscFv Antibody -PE40 Immunotoxin for Target Therapy of EGFR-Overexpressing Cancers. Iran J Biotechnol. 2018; 16(4): e1743.
Avand A, Akbari V, Shafizadegan S. In Vitro Cytotoxic Activity of a Lactococcus lactis Antimicrobial Peptide Against Breast Cancer Cells. Iran J Biotechnol. 2018; 16(3): e1867.
Bahadori M, Baharara J, Amini E. Anticancer Properties of Chrysin on Colon Cancer Cells, In vitro and In vivo with Modulation of Caspase-3, -9, Bax and Sall4. Iran J Biotechnol. 2016; 14(3): 177-184.
Behfarjam F, Rostamzadeh J, Zarei MA, Nikkhoo B. Association of Two Polymorphic Codons in P53 and ABCC1 Promoter with Prostate Cancer. Iran J Biotechnol. 2015; 13(1): 49-54.
Bordbar M, Darvishzadeh R, Pazhouhandeh M, Kahrizi D. An overview of genome editing methods based on endonucleases. Mod Genet J 2020; 15(2): 75-92.
Jamalzadeh L, Ghafoori H, Aghamaali M, Sariri R. Induction of Apoptosis in Human Breast Cancer MCF-7 Cells by a Semi-Synthetic Derivative of Artemisinin: A Caspase-Related Mechanism. Iran J Biotechnol. 2017; 15(3): 157-165.